Research Article

Research on Seismic Test and Calculation Model for Improving Factor of Composite Board with Heat Preservation Function

Table 5

Comparison of test and calculation results.

Result typesSpecimen no.PcrcrPy△yPu△u
(kN)(mm)(kN)(mm)(kN)(mm)

Test value178.70.85209.074.02369.6316.08
269.430.75220.254.11377.7117.72
371.570.83215.764.16366.4518.13
Avg.73.230.81215.034.1371.2617.31

Calculation value272.570.78224.043.98382.4917.66

Local error (%)4.5241.723.161.270.34

Global error (%)0.913.74.192.853.022.02