Research Article
Study of Electric Field Impact on Crystallization in Tunnel Drainage Pipes in Hard Water Area
Table 5
Contrast of scale inhibition rates circumferential electric field and parallel plate electric field patterns.
| | Electric field pattern (V) | Scale inhibition rate (%) |
| | 5 | Circumferential electric field | 44.25 | | Parallel plate electric field | 47.26 |
| | 12 | Circumferential electric field | 40.00 | | Parallel plate electric field | 31.78 |
| | 24 | Circumferential electric field | 32.47 | | Parallel plate electric field | 30.27 |
|
|