Research Article

Detection and Prediction of Internal-Caused Fire in Tunnel Cable by an Equivalent Transient Thermal Circuit Model

Table 4

The maximum value of the increased calculation accuracy value relative to the front level layering.

Number of layersMaximum value (°C)
Insulation layerInner sheathOuter sheath

55.233.12.7
101.811.361.15
200.70.540.51
300.20.160.16
500.10.110.1
1000.010.0210.021