| Pumping height (m) | Plastic viscosity () | Discharge (m3/h) | Calculated value (MPa) | Measured value (MPa) | Relative error (%) |
| 243 | 55 | 65 | 16.33 | 17.7 | −7.71 | 250 | 55 | 65 | 16.69 | 13.6 | 22.69 | 268 | 55 | 61 | 16.86 | 19 | −11.28 | 272 | 55 | 65 | 17.79 | 13.6 | 30.80 | 277 | 55 | 65 | 18.0 | 16 | −12.75 | 299 | 55 | 61 | 18.36 | 19 | −3.39 | 295 | 55 | 61 | 18.16 | 19 | −4.41 | 299 | 55 | 65 | 19.27 | 16 | 20.48 | 304 | 55 | 61 | 17.98 | 19 | −5.39 | 546.6 | 45 | 30 | 21.10 | 22.5 | −6.21 | 552.1 | 45 | 23 | 19.74 | 22 | −10.27 | 556.6 | 45 | 45 | 24.22 | 22.6 | 7.18 | 561.1 | 45 | 28 | 21.62 | 22.9 | −5.61 | 565.4 | 45 | 30 | 21.77 | 22.5 | −3.26 | 569.7 | 45 | 24 | 20.32 | 22.9 | −11.25 | 574 | 45 | 21 | 18.86 | 23.1 | −18.35 | 578.85 | 45 | 30 | 22.24 | 22.9 | −2.87 | 582.15 | 45 | 28 | 22.36 | 23.4 | −4.45 |
|
|