Research Article
Analysis of Concrete-Filled Steel Tube Reinforced Concrete Column-Steel Reinforced Concrete Beam Plane Frame Structure Subjected to Fire
Table 1
Fire resistance and failure mode of the frame structure.
| | | /min | Failure mode |
| 0.2 | 0.6 | 296 | The beam broke down | 0.4 | 0.6 | 139 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.6 | 57 | The frame beam and frame column were destroyed simultaneously | 0.8 | 0.6 | 17 | The frame beam and frame column were destroyed simultaneously |
| 0.6 | 0.2 | 92 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.4 | 67 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.6 | 57 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.8 | 39 | The frame beam and frame column were destroyed simultaneously |
|
|