Fire resistance and failure mode of the frame structure.

/minFailure mode

0.20.6296The beam broke down
0.40.6139The frame beam and frame column were destroyed simultaneously
0.60.657The frame beam and frame column were destroyed simultaneously
0.80.617The frame beam and frame column were destroyed simultaneously

0.60.292The frame beam and frame column were destroyed simultaneously
0.60.467The frame beam and frame column were destroyed simultaneously
0.60.657The frame beam and frame column were destroyed simultaneously
0.60.839The frame beam and frame column were destroyed simultaneously