Research Article
Analysis of Concrete-Filled Steel Tube Reinforced Concrete Column-Steel Reinforced Concrete Beam Plane Frame Structure Subjected to Fire
Table 2
Fire resistance unit: min.
| | | CFSTRC column | Composite column frame structure | Failure mode of frame structure |
| 0.2 | 0.6 | 582 | 296 | The beam broke down | 0.4 | 0.6 | 244 | 139 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.6 | 100 | 57 | The frame beam and frame column were destroyed simultaneously | 0.8 | 0.6 | 38 | 17 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.2 | 100 | 92 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.4 | 100 | 67 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.6 | 100 | 57 | The frame beam and frame column were destroyed simultaneously | 0.6 | 0.8 | 100 | 39 | The frame beam and frame column were destroyed simultaneously |
|
|