Research Article

Time Scale of Chloride-Induced Corrosion on Circular Section RC Linked Accelerated Test to Natural Corrosion

Table 5

Accelerated factor.

Chloride concentration (%)Voltage (V)Accelerated factor ()

1.551.3804
102.0184
206.0256
3529.8538

3.551.3804
101.9953
205.4954
3527.4499

5.051.3804
101.9498
205.2481
3525.7040