Research Article

Experimental Investigation and Load Capacity of Slender Cold-Formed Lipped Channel Sections with Holes in Compression

Table 2

Mean value of coupon tests.

t (mm)f0.2 (MPa)fu (MPa)E (MPa)εu (%)

0.806006022.16 × 1057.19