Research Article

Experimental Investigation and Load Capacity of Slender Cold-Formed Lipped Channel Sections with Holes in Compression

Table 5

Comparison on ultimate strength between the FEA results and predicted results using the modified method for columns with rectangular holes.

SpecimenL (mm)h (mm)b (mm)a (mm)t (mm)fy (MPa)S (mm)Hole numberHh (mm)Lh (mm)Pa (kN)Pc (kN)Pc/Pa

C8910-RH3-630008940131280500626.753.49.209.070.99
C8910-RH3-315008940131280500326.753.420.8522.951.10
C8910-RH3-16008940131280126.753.430.0730.031.00
C8910-RH5-630008940131280500644.5898.588.841.03
C8910-RH5-315008940131280500344.58921.3819.620.92
C8910-RH5-16008940131280144.58925.8123.920.93
C7012-RH3-630007035111.2350500621427.647.070.93
C7012-RH3-315007035111.23505003214226.1724.200.92
C7012-RH3-16007035111.23501214242.5542.991.01
C7012-RH5-630007035111.2350500635707.196.930.96
C7012-RH5-315007035111.23505003357023.0621.040.91
C7012-RH5-16007035111.23501357033.7731.280.93
C10010-RH3-63000100501215505006306013.5613.300.98
C10010-RH3-31500100501215505003306034.1632.050.94
C10010-RH3-1600100501215501306043.5242.020.97
C10010-RH5-630001005012155050065010013.1413.020.99
C10010-RH5-315001005012155050035010031.4029.370.94
C10010-RH5-160010050121550015010038.9636.560.94

Average0.965
Standard deviation0.049
Coefficient of variation0.051