Research Article

Study on the Static Performance of Prefabricated UHPC-Steel Epoxy Bonding Interface

Table 5

Test results.

TestSpecimen number (kN) (MPa) (MPa) (mm) (mm)

Direct shear testPS-E-1107.4304.770.0510.054
PS-E-2126.8105.640.0420.058
PS-E-3124.8105.550.0390.051
PS-E-5103.6004.600.0370.048
Tensile testPT-E-123.061.2300.0050.006
PT-E-425.461.3600.0050.006
PT-E-520.191.0800.0050.006
PT-E-619.491.0400.0050.006
Tensile-shear testST-E-227.910.930.540.3060.316
ST-E-330.141.000.580.3260.347
ST-E-437.181.240.720.3040.316
ST-E-632.041.070.620.3200.322

Note: is the ultimate bearing capacity of various specimens before failure; is the normal tensile strength of the interface before the failure of various specimens, the subscript represents the normal interface direction and represents that the specimen is in the ultimate loading state; is the tangential tensile strength of the interface before the failure of various specimens, the subscript represents the tangential interface direction, and represents that the specimen is in the ultimate loading state; is the displacement value corresponding to the ultimate bearing capacity ; is the ultimate displacement of various specimens(in particular, the displacement in the tensile-shear test is the average value of the dial indicator data).