Research Article

Research on the Seismic Performance of Straw Panel-Infilled Concrete Frame by Shaking Table Test

Table 6

Sensitivity and measuring range of sensors.

AccelerometerDisplacement meter
Measuring pointSensitivity (mV/m·s2)Measuring pointSensitivity (V/m)Measuring range (mm)

a110.02D16.21750
a29.92D26.15750
a39.90D36.13750
a410.16D46.08750
a59.92D54.581000
a610.38D64.571000
a710.22D74.571000