Research Article
Model Test Research on the Influence of Gate Blocking in Siltation Environment
Table 11
Verification analysis of the pull-out force of underwater (mixed) silt.
| Blocked objects | Measured value of blockage pull-out force (kN) | Calculated value of blockage pull-out force (kN) | Calculation error | Blockage height (m) | Blockage height (m) | Blockage height (m) | 0.2 | 0.3 | 0.4 | 0.5 | 0.2 | 0.3 | 0.4 | 0.5 | 0.2 | 0.3 | 0.4 | 0.5 |
| 1# steel plate | 0.181 | 0.287 | 0.358 | 0.419 | 0.180 | 0.279 | 0.364 | 0.440 | −0.30% | −2.65% | 1.75% | 4.91% | 2# steel plate | 0.106 | 0.174 | 0.227 | 0.285 | 0.120 | 0.186 | 0.243 | 0.293 | 13.50% | 7.05% | 6.98% | 2.83% | 3# steel plate | 0.067 | 0.096 | 0.129 | 0.155 | 0.060 | 0.093 | 0.121 | 0.147 | −10.22% | −2.98% | −5.88% | −5.47% |
|
|