Research Article
Model Test Research on the Influence of Gate Blocking in Siltation Environment
Table 6
Test results of pull-out resistance of the lower gate of the underwater mixed blockage.
| Blocked objects | Blockage height (m) | Overall height (m) | Blocked objects’ area (m2) | Blocked objects’ deadweight (kN) | Pull-out force of blockage (kN) | Silt : sand : small stone : medium stone | Combination 1 | Combination 2 | Combination 3 | Combination 4 | Combination 5 | 1 : 1 : 1 : 1 | 2 : 1 : 1 : 1 | 1 : 2 : 1 : 1 | 1 : 1 : 2 : 1 | 1 : 1 : 1 : 2 |
| 1# steel plate | 0.4 | 0.7 | 0.240 | 0.173 | 0.199 | 0.358 | 0.249 | 0.172 | 0.182 | 2# steel plate | 0.4 | 0.7 | 0.160 | 0.115 | 0.143 | 0.227 | 0.158 | 0.115 | 0.116 | 3# steel plate | 0.4 | 0.7 | 0.080 | 0.057 | 0.083 | 0.129 | 0.079 | 0.062 | 0.065 | 1# steel bar | 0.4 | 0.7 | 0.031 | 0.029 | 0.030 | 0.088 | 0.043 | 0.035 | 0.024 | 2# steel bar | 0.4 | 0.7 | 0.025 | 0.019 | 0.021 | 0.062 | 0.033 | 0.028 | 0.017 | 3# steel bar | 0.4 | 0.7 | 0.020 | 0.012 | 0.013 | 0.030 | 0.024 | 0.019 | 0.012 |
|
|