Research Article
Model Test Research on the Influence of Gate Blocking in Siltation Environment
Table 7
Results of pull-out force test of underwater (mixed) blockage.
| Blocked objects | Overall height (m) | Blocked objects’ deadweight (kN) | Pull-out force of blockage (kN) | Silt : sand : small stone : medium stone = 2 : 1:1 : 1 | Blockage height (0.20 m) | Blockage height (0.30 m) | Blockage height (0.40 m) | Blockage height (0.50 m) |
| 1# steel plate | 0.70 | 0.173 | 0.181 | 0.287 | 0.358 | 0.419 | 2# steel plate | 0.70 | 0.115 | 0.106 | 0.174 | 0.227 | 0.285 | 3# steel plate | 0.70 | 0.057 | 0.067 | 0.096 | 0.129 | 0.155 | 1# steel bar | 0.70 | 0.029 | 0.046 | 0.059 | 0.088 | 0.121 | 2# steel bar | 0.70 | 0.019 | 0.028 | 0.042 | 0.062 | 0.073 | 3# steel bar | 0.70 | 0.012 | 0.013 | 0.021 | 0.030 | 0.041 |
|
|