Research Article

Experimental Investigation on the Load-Carrying Capacity of Steel-to-Laminated Bamboo Dowel Connection I: Single Fastener with Slotted-In Steel Plate under Tension

Table 3

The comparison of the load-carrying capacity of the connections.

No.Experimental resultsTheoretical results
Fu (kN)Yield modeR (kN)Yield mode

T1-D1-L158.59II46.95II1.08
T2-D1-L121.15I23.80I1.14
T3-D1-L130.33II35.90II1.07
T4-D1-L140.45II41.77II1.09
T1-D2-L148.08III29.97III1.50
T1-D3-L162.49II56.54II1.11
T1-D4-L172.98II67.32II1.08