Research Article
Study on Properties of Drainage SBS Modified Asphalt Mixture with Fiber
Table 1
Technical indicators of 70 matrix asphalt.
| Test metric | Test result | Specification requirement | Test method |
| Needle penetration (25°C, 100 g, 5 s) (0.1 mm) | 68.2 | 60∼80 | T0604 | Softening point (ball and ring method) (°C) | 57.2 | ≥46.0 | T0606 | Ductility (5 cm/min, 15°C) (cm) | 106.3 | ≥100 | T0605 | Flash point (°C) | 268 | ≥260 | T0611 | Density (g·cm−3) | 1.025 | Actual measurement | T0603 | Solubility (%) | 99.7 | ≥99.5 | T0607 | After RTFOT | Mass variation (%) | −0.1 | −0.8∼+0.8 | T0610 | Penetration ratio (%) | 72.1 | ≥61 | T0604 | Ductility (5 cm·min−1, 15°C) (cm) | 7 | ≥6 | T0605 |
|
|