The peak temperature inside of the tunnel lining structure after the first 20 iterations (K).
| Longitudinal distance (m) | Point B | Point C | Point D | Point E |
| 0 | 304 | 293 | 287 | 309 | 5 | 710 | 564.6 | 453 | 600 | 10 | 859 | 844 | 610 | 966 | 15 | 907 | 987 | 934 | 1001 | 20 | 1010 | 951 | 1293 | 1145 | 25 | 1004 | 1090 | 1047 | 1105 | 30 | 1184 | 1176 | 1105 | 1081 |
|
|