Research Article
Modeling of Tunnel Concrete Lining under Fire and Explosion Damage
Table 2
The stable temperature inside of the tunnel lining structure after 200 iterations (K).
| | Longitudinal distance (m) | Point B | Point C | Point D | Point E |
| | 0 | 282 | 282 | 281.6 | 281.5 | | 5 | 411 | 368.2 | 290 | 383 | | 10 | 552 | 464 | 374 | 394 | | 15 | 604 | 445 | 487 | 417 | | 20 | 800 | 512 | 346 | 449 | | 25 | 661 | 659 | 624 | 471 | | 30 | 713 | 626 | 704 | 497 |
|
|