Research Article

Estimations of the Jacking Forces of Large-Sized Rectangular Jacking Pipes Based on a Displacement Control Method

Table 10

Comparison of jacking force estimation deviation for case B1 under different grouting pressure programs.

Jacking distance (m)Monitoring (kN)Program 1 (kN)Program 2 (kN)Optimal (kN)Theoretical (kN)

13.5Jacking force deviation15811.095585.779837.4114535.2513459.80
N/A−64.67%60.72%−8.07%−14.87%
28.5Jacking force deviation22437.699778.2420340.2522828.5917131.80
N/A−56.42%10.31%1.74%−23.65%
43.5Jacking force deviation26187.7512150.8126283.9327521.8720803.80
N/A−53.60%−0.37%5.09%−20.56%
58.5Jacking force deviation28815.1613813.1030448.2430810.1324475.80
N/A−52.06%−5.36%6.92%−15.06%
73.5Jacking force deviation30839.4515093.8133656.6433343.5728147.80
N/A−51.06%−8.37%8.12%−8.73%
88.5Jacking force deviation32486.4616135.8336267.0835404.8531819.80
N/A−50.33%−10.42%8.98%−2.05%