Research Article
Estimations of the Jacking Forces of Large-Sized Rectangular Jacking Pipes Based on a Displacement Control Method
Table 13
The deviation of the jacking force estimations for case B2.
| Jacking distance (m) | | Monitoring (kN) | The optimal estimation formula for case B1 (kN) | Theoretical estimation formula (kN) |
| 13.5 | Jacking force deviation | 19199.2476 | 14535.25 | 13459.80 | N/A | −24.29% | −7.40% | 28.5 | Jacking force deviation | 26240.99612 | 22828.59 | 17131.80 | N/A | −13.00% | −24.95% | 43.5 | Jacking force deviation | 30225.99908 | 27521.87 | 20803.80 | N/A | −8.95% | −24.41% | 58.5 | Jacking force deviation | 33018.00813 | 30810.13 | 24475.80 | N/A | −6.69% | −20.56% | 73.5 | Jacking force deviation | 35169.11767 | 33343.57 | 28147.80 | N/A | −5.19% | −15.58% | 88.5 | Jacking force deviation | 36919.31605 | 35404.85 | 31819.80 | N/A | −4.10% | −10.13% |
|
|
Note: : y = 11099ln ( x) − 14352; : y = 244.8 x + 10155. |