Research Article

Estimations of the Jacking Forces of Large-Sized Rectangular Jacking Pipes Based on a Displacement Control Method

Table 13

The deviation of the jacking force estimations for case B2.

Jacking distance (m)Monitoring (kN)The optimal estimation formula for case B1 (kN)Theoretical estimation formula (kN)

13.5Jacking force deviation19199.247614535.2513459.80
N/A−24.29%−7.40%
28.5Jacking force deviation26240.9961222828.5917131.80
N/A−13.00%−24.95%
43.5Jacking force deviation30225.9990827521.8720803.80
N/A−8.95%−24.41%
58.5Jacking force deviation33018.0081330810.1324475.80
N/A−6.69%−20.56%
73.5Jacking force deviation35169.1176733343.5728147.80
N/A−5.19%−15.58%
88.5Jacking force deviation36919.3160535404.8531819.80
N/A−4.10%−10.13%

Note: : y = 11099ln (x) − 14352; : y = 244.8x + 10155.