Research Article

Estimations of the Jacking Forces of Large-Sized Rectangular Jacking Pipes Based on a Displacement Control Method

Table 6

The calculation of jacking force based on the numerical simulation results (for case A1, driving distance 73.5 m, grouting pressure 0.13 MPa).

Element no.σ22 (N.m−2)Element no.σ22 (N.m−2)Element no.σ22 (N.m−2)

1−1.14E + 0613−9.94E + 0525−2.07E + 06
2−1.98E + 0614−9.93E + 0526−1.16E + 06
3−2.83E + 0615−7.00E + 0527−7.31E + 05
4−3.30E + 0616−5.38E + 0528−6.05E + 0
5−3.32E + 0617−6.05E + 0529−5.45E + 05
6−2.86E + 0618−7.36E + 0530−7.08E + 05
7−2.02E + 0619−1.18E + 0631−9.96E + 05
8−1.18E + 0620−2.09E + 0632−9.87E + 05
9−7.44E + 0521−2.97E + 0633−7.04E + 05
10−6.07E + 0522−3.41E + 0634−5.45E + 05
11−5.73E + 0523−3.40E + 0635−5.72E + 05
12−7.23E + 0524−2.95E + 0636−7.08E + 05

No. 1–36 element average of  = 1.45E + 06 N/m2. The area of pipe section was 12.98 m2. The jacking force = 1.45E + 06 12.98 = 18818.21 kN.