Research Article

Research on Monitoring Method of Remote Deformation and System Application Based on Image

Table 3

Experimental table comparing the accuracy of the L1 target in the vertical direction.

Serial numberMonitoring timeTarget readingS1 (mm)S2 (mm)S3 (mm)P1 (mm)P2 (mm)

114 : 470.0
214 : 493.53.53.73.50.20.0
314 : 518.48.48.68.40.20.0
414 : 5311.811.811.711.7−0.1−0.1
514 : 5518.418.418.518.30.1−0.1
614 : 5634.034.033.934.0−0.10.0
715 : 0312.512.512.612.40.1−0.1
815 : 056.36.36.56.30.20.0
915 : 0715.415.415.315.3−0.1−0.1
1015 : 0922.522.522.822.40.3−0.1
1115 : 1128.728.728.828.70.10.0
1215 : 1222.422.422.622.60.20.2
1315 : 1331.531.531.431.4−0.1−0.1
1415 : 1436.436.436.336.4−0.10.0
1515 : 1624.024.024.124.00.10.0
1615 : 1716.516.516.416.6−0.10.1

Average deviation0.140.06