Research Article

An Automatic Measurement Method of Test Beam Response Based on Spliced Images

Table 4

Deflection measurement deviation of a single image and spliced image.

LocationDial indicator (mm)Image-based measurement (mm)Deviation (%)

1/4−6.99Single image−6.960.43
Spliced image−7.020.43
1/2−7.75Single image−8.084.26
Spliced image−8.003.12
3/4−5.09Single image−5.375.50
Spliced image−5.303.99