Table 5
Contrast of temperature data of control points at midline.
| Measuring point | T0 (°C) | T21 (°C) | ΔT (°C) | V (°C/h) | Time of temperature below freezing point (h) | Δt (h) |
| m2 | 19.8 | −0.6 | −4.4 | −0.97 | 21 | −9 | m2∗ | 22.2 | −5.0 | −1.30 | 12 | m6 | 19.2 | −0.7 | −3.1 | −1.03 | 21 | −7 | m6∗ | 21.6 | −3.8 | −1.21 | 14 |
|
|