Research Article

Freezing Temperature Field of FSPR under Different Pipe Configurations: A Case Study in Gongbei Tunnel, China

Table 5

Contrast of temperature data of control points at midline.

Measuring pointT0 (°C)T21 (°C)ΔT (°C)V (°C/h)Time of temperature below freezing point (h)Δt (h)

m219.8−0.6−4.4−0.9721−9
m222.2−5.0−1.3012
m619.2−0.7−3.1−1.0321−7
m621.6−3.8−1.2114