Research Article
Study on Tunnel Air Curtain Insulation System for Cold Areas
Table 5
Measured data and calculated values of air curtain on main slope.
| External temperature/°C | External wind speed/(m/s) | Wind speed after the air curtain starts(m/s) | Measured barrier efficiency/% | Calculated barrier efficiency/% | Error/% |
| 4∼8 | 2.28 | 0.63 | 72.2 | 77.79 | 7.7 | 0 | 3.27 | 1.51 | 54.0 | 54.24 | 0.44 | −10 | 5.60 | 3.05 | 45.5 | 31.67 | 30.4 |
|
|