Research Article
Optimization and Prediction of Energy Consumption, Daylighting, and Thermal Comfort of Buildings in Tropical Areas
Table 8
Comparative analysis of Pareto optimal solutions and initial solution.
| Office room style | Initial solution | Option 1 | Option 2 | Option 3 |
| WWR of north | 0.2 | 0.2 | 0.19 | 0.22 | WWR of west | 0.2 | 0.11 | 0.11 | 0.11 | WWR of south | 0.3 | 0.1 | 0.10 | 0.10 | WWR of east | 0.2 | 0.12 | 0.12 | 0.14 | Window height | 3.0 | 3.4 | 3.4 | 3.4 | Number of horizontal panels | 10 | 16 | 16 | 16 | Depth of louvers | 7 | 9 | 9 | 9 | Angle of louvers | 0 | −1 | −1 | −1 | UDI (−%) | −72.59 | −73.67 | −72.91 | −74.09 | Cooling load (kWh/m2) | 176.58 | 163.01 | 162.87 | 163.38 | PMV | 1.13 | 0.83 | 0.82 | 0.84 |
|
|