Research Article
Column Study for Adsorption of Copper and Cadmium Using Activated Carbon Derived from Sewage Sludge
Table 3
Column performance in cadmium removal at different bed depths.
| Z (cm) | Flow rate (mL/min) | IMC mg/L | Breakthrough time (min) | Exhausting time (min) | M total (g) | Removal % | qe (mg/g) |
| 3 | 2 | 100 | 5 | 450 | 90 | 71.41 | 28.6 | 6 | 2 | 100 | 10 | 540 | 108 | 70.93 | 11.75 | 9 | 2 | 100 | 30 | 840 | 168 | 64.2 | 11.02 |
|
|