Research Article
Temperature Field of Concrete-Filled Steel Tubular Arch Bridges and Its Application
Table 3
The calculation results of the nonuniform temperature.
| | 
 |  | Schemes | Temperature of upper steel tube (°C) | Temperature of lower steel tube (°C) | Temperature of left steel tube (°C) | Temperature of right steel tube (°C) | Temperature of upper concrete (°C) | Temperature of lower concrete (°C) | Inner concrete temperature (°C) |  | 
 |  | 4 am |  | Scheme 1 | 11.2 | 21 | 11 | 39.8 | 11.4 | 11.4 | 49.6 |  | Scheme 2 | 12 | 22 | 11 | 40 | 11.6 | 11.6 | 50.4 |  | Scheme 3 | 13 | 25 | 12 | 41 | 12 | 12 | 51 |  | Scheme 4 | 16.2 | 29 | 16 | 41.7 | 16.4 | 16.4 | 49.2 |  | Scheme 5 | 15.3 | 26 | 14 | 41 | 14.5 | 14.5 | 50 |  | Scheme 6 | 11.8 | 20 | 10 | 39 | 11.9 | 11.9 | 51 |  | Scheme 7 | 9 | 17 | 8 | 37 | 11.9 | 11.9 | 50 |  | 
 |  | 2 pm |  | Scheme 1 | 48.7 | 27.8 | 35 | 35 | 46 | 27.9 | 48.6 |  | Scheme 2 | 51.7 | 28 | 38 | 38 | 49 | 28.3 | 50.4 |  | Scheme 3 | 55 | 28.4 | 40 | 40 | 52 | 28.6 | 55 |  | Scheme 4 | 46.3 | 26.1 | 36 | 36 | 45 | 26.4 | 48 |  | Scheme 5 | 51.8 | 27.6 | 38 | 38 | 51.7 | 27.8 | 51 |  | Scheme 6 | 52 | 28.4 | 38 | 38 | 51.7 | 28.6 | 54.5 |  | Scheme 7 | 50 | 28.4 | 36 | 36 | 51 | 29 | 54.2 |  | 
 | 
 |