Research Article
Structural Damage Localization in Plates Using Global and Local Modal Strain Energy Method
Table 9
Damage capacity indicators for the second preliminary damaged area.
| Mesh size | Indicator | Damage threshold | 20% | 30% | 40% | 50% | 60% | 70% |
| 5% | A (%) | 100 | 100 | 67 | 67 | 67 | 33 | B (%) | 1400 | 1400 | 933 | 933 | 683 | 467 |
| 4% | A (%) | 100 | 100 | 67 | 67 | 67 | 33 | B (%) | 860 | 860 | 573 | 573 | 573 | 287 |
| 2% | A (%) | 100 | 100 | 100 | 100 | 100 | 100 | B (%) | 380 | 300 | 300 | 220 | 220 | 100 |
| 1% | A (%) | 100 | 100 | 100 | 100 | 100 | 100 | B (%) | 200 | 70 | 0 | 0 | 0 | 0 |
|
|