Investigation on the Effect of Geometric Parameter on Reinforced Concrete Exterior Shear Wall-Slab Connection Using Finite Element Analysis

Table 3

Detailing for both reinforced concrete slab and shear wall for the connections.

No.Denoted bySlab reinforcementShear wall reinforcement
LongitudinalTransverseVerticalHorizontalStirrups

1C1SWS1ɸ4 mm@96 mmɸ4mm@96 mm∅6c/c 90 mm vertical bar on both faces of shear wall∅4c/c 130 mm horizontal bar on both faces of shear wall∅2mmc/c 130 mm
2C1SWS2ɸ4 mm@70 mmɸ4mm@66 mm
3C1SWS3ɸ4 mm@53 mmɸ4mm@53 mm
4C2SWS1ɸ4 mm@96 mmɸ4mm@93 mm
5C2SWS2ɸ4 mm@70 mmɸ4 mm@66 mm
6C2SWS3ɸ4 mm@53 mmɸ4 mm@53 mm
7C3SWS1ɸ4 mm@96 mmɸ4 mm@93 mm
8C3SWS2ɸ4 mm@70 mmɸ4mm@66 mm
9C3SWS3ɸ4 mm@50 mmɸ4 mm@50 mm
10C4SWS1ɸ4 mm@96 mmɸ4 mm@93 mm
11C4SWS2ɸ4 mm@70 mmɸ4 mm@66 mm
12C4SWS3ɸ4mm@50 mmɸ4mm@50 mm
13C1SWS1-1ɸ4 mm@96 mmɸ4 mm@96 mm
14C1SWS1-2ɸ4 mm@96 mmɸ4 mm@96 mm
15C1SWS1-3ɸ4 mm@96 mmɸ4 mm@96 mm
16C1SWS1-4ɸ4 mm@96 mmɸ4 mm@96 mm