Research Article
Overlapping Decentralized Control Strategies of Building Structure Vibration Based on Fault-Tolerant Control under Seismic Excitation
Table 1
Maximum interstory displacement.
| Stories | No control | Case1 (cm (%)) | Case2 (cm (%)) | Case3 (cm (%)) |
| 1 | 1.803 | 0.744 (58.74) | 0.856 (52.50) | 0.939 (47.92) | 2 | 1.480 | 0.650 (56.08) | 0.773 (47.77) | 0.798 (46.10) | 3 | 1.580 | 0.570 (63.92) | 0.816 (48.35) | 0.862 (45.47) | 4 | 1.545 | 0.650 (57.93) | 0.794 (48.61) | 0.866 (43.95) |
|
|