Research Article
Influence of Multistage Target Temperature and Cyclic Loading/Unloading on the Permeability of Polypropylene Fiber Concrete
Table 2
Test results of PPFRC loading permeability under different temperatures.
| State of stress | Stress ratio (R) | Permeability (kg/×10−17 m2) | 22°C | 40°C | 80°C | 120°C | 160°C | 200°C | 240°C | 280°C |
| Graded cyclic loading | 0.03 | 1.85 | 2.31 | 8.02 | 29.65 | 127.43 | 397.21 | 513.52 | 532.75 | 0.10 | 1.71 | 2.13 | 7.46 | 27.79 | 119.11 | 373.92 | 491.66 | 512.42 | 0.17 | 1.56 | 1.96 | 6.90 | 25.71 | 109.45 | 350.32 | 462.12 | 487.28 | 0.23 | 1.41 | 1.78 | 6.35 | 23.68 | 101.04 | 330.75 | 436.64 | 463.87 | 0.30 | 1.27 | 1.60 | 5.78 | 21.76 | 93.11 | 313.45 | 414.04 | 441.54 | 0.37 | 1.16 | 1.44 | 5.27 | 19.78 | 86.32 | 298.34 | 403.91 | 433.56 | 0.43 | 1.07 | 1.32 | 4.92 | 18.31 | 83.11 | 290.25 | 398.36 | 428.74 | 0.50 | 1.01 | 1.26 | 4.77 | 17.65 | 81.71 | 287.27 | 395.82 | 425.74 |
| Graded single loading | 0.03 | 1.85 | 2.31 | 8.02 | 29.65 | 127.43 | 397.21 | 513.51 | 532.70 | 0.10 | 1.69 | 2.10 | 7.41 | 27.38 | 118.11 | 367.92 | 483.66 | 506.42 | 0.17 | 1.53 | 1.91 | 6.77 | 25.22 | 107.95 | 343.32 | 456.12 | 479.28 | 0.23 | 1.37 | 1.72 | 6.14 | 23.01 | 99.04 | 319.75 | 428.64 | 453.07 | 0.30 | 1.22 | 1.54 | 5.51 | 20.89 | 91.11 | 301.45 | 404.04 | 429.54 | 0.37 | 1.08 | 1.37 | 5.00 | 18.87 | 84.32 | 286.34 | 390.01 | 414.56 | 0.43 | 0.97 | 1.23 | 4.59 | 17.31 | 80.11 | 278.25 | 380.36 | 404.74 | 0.50 | 0.90 | 1.16 | 4.35 | 16.43 | 76.71 | 271.27 | 371.82 | 397.74 |
|
|