Concrete Production and Curing with Recycled Wastewater: A Review on the Current State of Knowledge and Practice

Table 2

Determined values of recycled wastewater quality parameters vs maximum allowable limits as per IS 456:2000 [36].

S/NAuthorType of wastewater used to produce concreteParameters analysedValues obtainedMax. tolerable limitsIS 456: 2000 limits [36]Comparison with max. limitsComparison with IS 456: 2000 limits [36]

1Tay and Yip [29]Wastewater is treated through coagulation, flocculation, sedimentation, filtration, aeration, and chlorination, at increasing concentrations from 25–100% of potable water.Colour13
Turbidity1.52000WithinN/A
BOD52N/AN/A
COD35N/AN/A
NO2-N0.2N/AN/A
NH4-N16N/AN/A
NO3-N2.5N/AN/A
TH-CaCO3140N/AN/A
pH7.19>6WithinWithin
SS3.220002000WithinWithin
TS67050000WithinN/A
TA-CaCO3110500WithinN/A
CaCO31000
HCO3-102400WithinN/A
Sulphates563000400WithinWithin
Chlorides24045002000WithinWithin

2Su, et al. [42]The wash water from concrete mixer washout operationspH11.639>6HigherWithin
Turbidity-187.332000WithinN/A
TS4196.6750000WithinN/A
Chlorides16.3445002000WithinWithin
Sulphates2163000400WithinWithin

3Al-Ghusain and Terro [19]Preliminary (PT), secondary (ST) and tertiary (TT) treated wastewaterPTSTTT
TS98686777350000WithinN/A
Sulphate2301801603000400WithinWithin
NO3-N00.41.9N/AN/A
NO2-N000.6N/AN/A
Chloride28729034045002000WithinWithin
NH4374436N/AN/A
COD4076129N/AN/A
Alkalinity-CaCO32286657500WithinN/A
Sulphide0.900.2N/AN/A
Total Cl001.71N/AN/A
Res. free Cl000.18N/AN/A

4Silva and Naik [43]Primary (PT), secondary (ST) and tertiary (TT) treated wastewaterPTSTTT
TSS86620002000WithinWithin
BOD51835N/AN/A
NH4-N0.2N/AN/A
P0.3N/AN/A
Faecal coli MPN/100 ml5000040N/AN/A

5Al-jabri and Taha [33]Wastewater from car washing stationpH6.949>6WithinWithin
Electrical resistivity (μs/cm)498N/AN/A
TDS25450000WithinN/A
Tot. Alkalinity90500WithinN/A
HCO3-90400WithinN/A
Carbonates01000WithinN/A
Hydroxide0N/AN/A
Tot. Hardness152N/AN/A
Ca + Mg + Na + K253.7<2000WithinN/A
Iron0.1N/AN/A
F(PPM)0.97N/AN/A
Cl(PPM)74.245002000WithinWithin
Br (PPM)0.22N/AN/A
(PPM)0.07500WithinN/A
(PPM)8.14100WithinN/A
SO4 (PPM)97.73000400WithinWithin
SiO2 (PPM)9.56N/AN/A

6Noruzman, et al. [44]The secondary treated effluents from heavy industry (HI), a palm-oil mill (POM), and domestic sewage (DS)HIDSPOM
pH8.87.218.149>6WithinWithin
Total solids3445112124050000WithinN/A
SS178232020002000WithinWithin
Total alkalinity44915960500WithinN/A
Sulphates56.722.625.43000400WithinWithin
Chlorides2257.55.245002000WithinWithin
Ca + Mg + Na + K31.74.64.12000WithinN/A
Nitrate1137.545500WithinN/A
Iron1.5200N/AN/A
Copper0.3900600WithinN/A
Lead0.180.0070.003600WithinN/A
Zinc0.440.210.13600WithinN/A
Manganese0.7560.0110.028600WithinN/A

7Asadollahfardi, et al. [17]Treated domestic wastewater before chlorinationpH7.79>6WithinWithin
Turbidity122000WithinN/A
Sulphates1803000400WithinWithin
Nitrates14500WithinN/A
Nitrites3.6N/AN/A
Chlorides5545002000WithinWithin
Total solids20050000WithinN/A
TSD3020002000WithinWithin
BOD530N/AN/A
TDS170500002000WithinWithin
COD93N/AN/A

8Ghrair, et al. [45]Raw (RGW) and treated grey (TGW) water from grey water treatment plantRGWTGW
TSD436220002000WithinWithin
TDS980803500002000WithinWithin
COD9006.97N/AN/A
BOD55362.98N/AN/A
Chlorides24320845002000WithinWithin
Sulphates2221373000400WithinWithin
pH7.57.99>6WithinWithin
E. Coli (MPN/100 ml)1.70E + 05<1N/AN/A
NH324>4.5N/AN/A

9Meena and Luhar [27]Secondary (ST) and tertiary (TT) treated wastewaterSTTT
BOD52014N/AN/A
Hardness as CaCO3256248N/AN/A
Chlorides269.91257.9245002000WithinWithin
Turbidity (NTU)0.3050.5862000WithinN/A
pH7.4879>6WithinWithin
Conductivity (μs/cm)1.591.59N/AN/A

N/A = not available, SS = suspended solids; TS = total solids; TSS = total suspended solids.