Research Article

Effect of Axial Compression Ratio on Seismic and Self-Centering Performance of Unbonded Prestressed Concrete Columns

Table 2

Axial compression ratios of specimens.

Specimen numberAxial compression ratio Preloaded axial compression ratio Applied axial compression ratio Applied axial compression kN

PTRC-10.15—0.15238.05
PURC-10.550.400.15238.05
PURC-20.450.400.0579.35
PURC-30.650.400.25396.75
PURC-40.400.250.15238.05