Numerical Simulation Study on Construction Effect of Top-Down Construction Method of Suspended Diaphragm Wall for Deep and Large Foundation Pit in Complex Stratum
Table 5
Summary of the corresponding depth of the maximum bending moment of the suspended foot connecting wall.
Working procedure
Suspended foot diaphragm wall (west, the length is 45.82 m)
Suspended foot diaphragm wall (east, the length is 51.98 m)
Maximum bending moment (kN∙m/m)
The depth of the diaphragm wall (m)
Maximum bending moment (kN∙m/m)
The depth of the diaphragm wall (m)
The first excavation (−2.000 m)
383.553/−154.641
−34.37/−43.53
495.496/−183.378
−38.99/−49.38
The third excavation (−13.400 m)
732.862/−311.066
−27.49/−43.53
1127.781/−404.225
−20.79/−49.38
The fifth excavation (−24.550 m)
2080.852/−600.905
−34.37/−43.53
3621.628/−1118.857
−33.79/−49.38
The seventh excavation (−34.145 m)
2654.072/−250.395
−34.37/−43.53
4654.927/−1193.643
−38.99/−49.38
The tenth excavation (−51.630 m)
2596.608/−469.726
−34.37/−43.53
4251.651/−42.949
−38.99/−51.98
Remarks