Research Article

Full-Scale Laboratory Test of Cutting Large-Diameter Piles Directly by Shield Cutterhead

Table 3

Test results for cutting C35 reinforced concrete layer with disc cutters.

Position of cutPenetration speed (mm/min)Rotating speed (r/min)Total thrust (kN)Torque (kN·m)Evaluation of test results
Ave.Max.Ave.Max.

Concrete layer9.470.61194272No stuck, low efficiency
17.250.613862387Stuck
6.471.032500200No stuck, low efficiency
Reinforced concrete layer8.360.5729803512206275Relatively stable
13.300.5132004052200381Stuck