Research Article

Spatial Numerical Simulation of Locally Corroded Steel Plate Girder with Various End Panels

Table 2

Improvement in the capacity of corroded plate girder by welding end plates.

Damage depth, d (mm)Residual thickness, (t/to)Peak Load, (kN)Capacity enhancement
Nonrigid end post Figure 11(b)With health end plate Figure 11(d)

2040%1472166413.03%
30%108811929.48%
25%8929799.69%
20%69176811.14%

4040%140015188.48%
30%102811239.19%
25%8509279.00%
20%66073110.88%

6040%136214969.90%
30%100811079.82%
25%8299089.57%
20%65072211.11%

8040%1325148812.35%
30%982109411.41%
25%81490511.21%
20%59671419.84%

10040%1312148713.32%
30%981108610.76%
25%76187715.29%
20%58271422.71%