Research Article

Axial Compression Test and Bearing Capacity Analysis of Biaxial Prestressed Angle Steel Plate Fully Wrapped Reinforced Concrete Short Column

Table 4

Comparison of experimental and calculated values.

Numberfc (MPa)Prestress (MPa)Nm/kNNt/kNNm/Nt

CC30.1—1413.561409.801.02
RC130.101955.221912.041.02
RC230.1179.52171.832152.221.01
RC330.13402271,392279.911.00