Effect of Fiber Treatments on the Mechanical Properties of Sisal Fiber-Reinforced Concrete Composites
Table 8
ANOVA test for the compressive strength of SFRC.
Source of variation
SS
df
MS
F
value
crit
7 days
Alkali concentration
134.29
3
44.76
47.08
0
3.01
Significant
Soaking time
15.52
2
7.76
8.16
0.002
3.4
Significant
Interaction
10.87
6
1.81
1.91
0.121
2.51
Insignificant
Within
22.82
24
0.95
Total
183.5
35
28 days
Alkali concentration
174.03
3
58.01
51.64
0
3.01
Significant
Soaking time
7.77
2
3.89
3.46
0.048
3.4
Significant
Interaction
24.76
6
4.13
3.67
0.01
2.51
Significant
Within
26.96
24
1.12
Total
233.52
35
Significant at 5% probability (). df, degrees of freedom; F, F-test for ANOVA two-way; MS, mean square; SS, sum of squares; value, calculated probability.