Research Article

Field Temperature Data Analysis of the Water Resistance Performance of Freeze-Sealing Pipe Roof Used in Tunnel through Water-Rich Strata

Table 2

Thickness of the frozen soil wall calculated by the selected measuring points of the middle and lower soil.

Near east shaftAt the middleNear west shaft
Selected measuring pointThickness of calculated frozen soil (m)Selected measuring pointThickness of calculated frozen soil (m)Selected measuring pointThickness of calculated frozen soil (m/m)

D16-01-S33.69D16-08-S34.17D16-29-S32.05
D16-02-S32.58D16-13-S35.03D16-30-S31.64
D16-03-S32.23D16-14-S33.72D16-31-S32.66
D30-01-S32.31D30-08-S33.71D26-29-S12.73
D30-02-S33.70D30-10-S35.85D26-30-S12.93
D30-03-S33.85D30-13-S33.16D26-31-S12.32
D30-04-S33.05D30-16-S32.30D26-32-S12.00