Research Article
The Effect of Steel Fibers on the Interlocking Length between Reinforcement and Concrete and on Compressive Strength of Concrete
Table 2
Properties of aggregates and steel fibers used for 1 m3 of concrete mixture.
| Aggregates | Specific weight (g/cm3) | Amount used (kg) | Mixture rates (%) | Water absorption percentage |
| 0/4 mm aggregate | 2.64 | 1217−1200 | 50 (±1) | 1.6 | 4/11 mm crushed stone aggregate | 2.77 | 278−256 | 10 (±1) | 0.8 | 11/22 mm crushed stone aggregate | 2.71 | 476–491 | 20 (±1) | 0.8 | Concrete fiber® BF0960 Steel Fiber | Standard | ASTM A820/A820M-04, type 1 cold drawn wire | Appearance | Hooked fiber, bright, steel wire
| Type | Cold drawn | Edge | Corrugated | Angle | 45° | Fiber length | 60 mm | Diameter | 0.9 mm | Tensile strength | 1100 MPa | Slenderness ratio | 66 |
|
|