Research Article
The Research on Obtaining the Geometric Dimension of Cable-Stayed Bridges Based on 3D Laser Scanning
Table 1
Scanning parameters of Leica Scan Station P40 [
16].
| | Parameters | Data |
| | Distance accuracy | 1.2 mm + 10 ppm | | Point accuracy | 3 mm@50 m; 6 mm@50 m | | Target acquisition accuracy | 2 mm@50 m | | Noise range | 0.4 mm·rms@10 m; 0.5 mm·rms@50 m | | Scanning rate | 1 million points/s | | Scanning range | 360° horizontally; 290° vertically |
|
|