Research Article

Experimental Study on Two-Step Concrete Corbels with Several Interface Conditions

Table 1

Summary of geometry and interface surface conditions of the tested specimens.

Specimen IDDimensions of the section of corbel () (mm)fcu (MPa)Interface surface condition

M1200 × 30032Control, monolithically
M2Contact surface mean roughness depth = 4 mm
M3Contact surface mean roughness depth = 8 mm
M4Using epoxy adhesive without surface roughness
M5Implanted main steel reinforcement and vertical stirrups
M6Implanted main steel reinforcement only

Note. b, width of corbel; h, height of corbel.