Table 2

The floor distribution and component information of TMSR-LF1.

PartFloorThickness and section dimensions (mm)
Shear wallFloor slabBeamColumnInfill wall

A1–3800–1,200200–1,800
B4–6240150–200400 × (600–700)600 × 600
C4–8200–1,000150–200400 × (450–900)600 × 600240