Rebound hammer data at 16 points on the face of the wall chamber.
| S. no. | Direction of hammer | Rebound point | Rebound number | Average rebound number | Compressive strength (MPa) | Compressive strength (psi) |
| 1 | A | A1 | 28 | 29 | 21 | 3,045 | 2 | A2 | 28 | 3 | A3 | 29 | 4 | A4 | 28 | 5 | B1 | 26 | 6 | B2 | 28 | 7 | B3 | 29 | 8 | B4 | 28 | 9 | C1 | 30 | 10 | C2 | 31 | 11 | C3 | 31 | 12 | C4 | 30 | 13 | D1 | 31 | 14 | D2 | 32 | 15 | D3 | 28 | 16 | D4 | 34 |
|
|
According to ASTM C 805-18: rebound number = 29 rebound number (average).
|