Research Article

Thermal Performance Assessment of Concrete Walls Using Different Phase Change Materials

Table 4

Rebound hammer data at 16 points on the face of the wall chamber.

S. no.Direction of hammerRebound pointRebound numberAverage rebound numberCompressive strength (MPa)Compressive strength (psi)

1AA12829213,045
2A228
3A329
4A428
5B126
6B228
7B329
8B428
9C130
10C231
11C331
12C430
13D131
14D232
15D328
16D434

According to ASTM C 805-18: rebound number = 29 rebound number (average).