Research Article

Research on 3D Measurement and Rapid Location Technique for Assembling the Special-Shaped Structural Segments

Table 2

Results of Case 1 and Case 3.

Scaling factorSk (106 mm2)ΔU (mm)Max/Min (θ)Max (Sk)/Skδ = ΔU/ΔP
αCase 1Case 3Case 1Case 3Case 1Case 3Case 1Case 3Case 1Case 3

0.010.000.00798.4688.41.403.510,183.09,890.4226.2195.0
0.020.000.00399.7345.71.393.52,496.72,492.7113.297.9
0.040.010.01171.2173.01.413.5630.2622.848.549.0
0.060.020.03113.1114.61.413.5278.3276.832.032.5
0.080.030.0499.885.51.413.5156.5156.328.324.2
0.100.050.0767.067.81.423.599.999.919.019.2
0.150.100.1552.144.31.413.544.544.414.812.5
0.200.180.2738.532.61.413.525.025.010.99.2
0.250.280.4325.425.51.413.516.016.07.27.2
0.300.400.6120.820.81.413.511.111.15.95.9
0.350.550.8317.617.41.413.58.28.25.04.9
0.400.721.0915.114.91.413.56.26.24.34.2
0.450.911.3813.213.01.413.54.94.93.73.7
0.501.121.7011.711.41.413.54.04.03.33.2
0.601.612.4511.49.11.413.52.82.83.22.6
0.702.193.339.67.51.413.52.02.02.72.1
0.802.864.358.35.91.413.51.61.62.41.7
0.903.635.507.35.61.413.51.21.22.11.6
1.004.486.796.55.31.413.51.01.01.91.5