Research Article
Optimal Mix Design and Mechanical Properties of Rapid-Hardening Foam Concrete
Table 4
Orthogonal experiment, each group with three specimens, 1-day compressive strength error percentage.
| Test number | Specimen 1 Compressive strength (MPa) | Specimen 2 Compressive strength (MPa) | Specimen 3 Compressive strength (MPa) | Average compressive strength (MPa) | Percentage of error between specimen 1 and average (%) | Percentage of error between specimen 2 and average (%) | Percentage of error between specimen 3 and average (%) |
| 1 | 1.8177 | 1.6437 | 1.6548 | 1.7054 | 6.6 | 3.6 | 3.0 | 2 | 2.5411 | 2.7990 | 2.3011 | 2.5471 | 0.2 | 9.9 | 9.7 | 3 | 2.2969 | 2.2929 | 1.9991 | 2.1963 | 4.5 | 4.4 | 9.0 | 4 | 0.8513 | 0.8531 | 0.8504 | 0.8510 | 0.0 | 0.2 | 0.0 | 5 | 0.2314 | 0.4581 | 0.4159 | 0.3685 | 37 | 24% | 13 | 6 | 0.8781 | 0.8865 | 0.8960 | 0.8869 | 0.9 | 0.0 | 1.0 | 7 | 0.1120 | 0.1416 | 0.2397 | 0.1645 | 32 | 14 | 46 | 8 | 2.0474 | 1.9692 | 1.8988 | 1.9718 | 3.8 | 0.1 | 3.7 | 9 | 1.9687 | 1.9687 | 2.1232 | 2.0202 | 2.5 | 2.5 | 5.1 |
|
|