Research Article

Optimal Mix Design and Mechanical Properties of Rapid-Hardening Foam Concrete

Table 4

Orthogonal experiment, each group with three specimens, 1-day compressive strength error percentage.

Test numberSpecimen 1 Compressive strength (MPa)Specimen 2 Compressive strength (MPa)Specimen 3 Compressive strength (MPa)Average compressive strength (MPa)Percentage of error between specimen 1 and average (%)Percentage of error between specimen 2 and average (%)Percentage of error between specimen 3 and average (%)

11.81771.64371.65481.70546.63.63.0
22.54112.79902.30112.54710.29.99.7
32.29692.29291.99912.19634.54.49.0
40.85130.85310.85040.85100.00.20.0
50.23140.45810.41590.36853724%13
60.87810.88650.89600.88690.90.01.0
70.11200.14160.23970.1645321446
82.04741.96921.89881.97183.80.13.7
91.96871.96872.12322.02022.52.55.1