Orthogonal experiment, each group with three specimens, 3-day compressive strength error percentage.

Test numberSpecimen 1 Compressive strength (MPa)Specimen 2 Compressive strength (MPa)Specimen 3 Compressive strength (MPa)Average compressive strength (MPa)Percentage of error between specimen 1 and average (%)Percentage of error between specimen 2 and average (%)Percentage of error between specimen 3 and average (%)

12.54112.32482.46852.44483.94.91.0
23.19153.48142.90163.19150.09.19.1
32.81142.81602.81602.81450.10.00.0
40.37010.55020.58360.5013269.816
50.50210.43830.43180.45749.84.25.6
60.88690.82001.18361.0018111818
71.05921.04491.07701.06040.11.51.6
81.86271.56681.71681.71548.68.70.0
91.99881.79711.63371.8099100.79.7