Research Article
Fuzzy Algorithm for Power Transformer Diagnostics
Table 3
Comparison of accuracy of different methods.
| | ā | | | | |
| | Doernenburg | 77 | 111 | 69.37 | 38.50 | | Roger | 89 | 145 | 61.38 | 44.50 | | IEC | 142 | 170 | 83.53 | 71.00 | | Duval Triangle | 172 | 200 | 86.00 | 86.00 | |
Li et al. [12] | 181 | 200 | 90.50 | 90.50 | | Proposed method | 187 | 200 | 93.50 | 93.50 |
|
|