Research Article
Parameter Sensitivity Analysis and Optimization of the Single-Layer Urban Canopy Model in the Megacity of Shanghai
Table 1
SLUCM input parameters selected for analysis, value space, and default values.
| Parameter | Min. | Max. | Default | Definition (unit) |
| ALBR | 0.05 | 0.4 | 0.2 | Roof albedo (-) | ALBB | 0.05 | 0.55 | 0.2 | Wall albedo (-) | ALBG | 0.05 | 0.3 | 0.2 | Road albedo (-) | EPSR | 0.85 | 0.98 | 0.9 | Roof emissivity (-) | EPSB | 0.85 | 0.98 | 0.9 | Wall emissivity (-) | EPSG | 0.85 | 0.98 | 0.9 | Road emissivity (-) | AKSR | 0.04 | 1.74 | 0.67 | Roof conductivity (W/m/K) | AKSB | 0.04 | 1.74 | 0.67 | Wall conductivity (W/m/K) | AKSG | 0.04 | 1.74 | 0.67 | Road conductivity (W/m/K) | CAPR | 0.1 E6 | 2.3 E6 | 1 E6 | Roof capacity (J m−3K−1) | CAPB | 0.1 E6 | 2.2 E6 | 1 E6 | Wall capacity (J m−3K−1) | CAPG | 0.3 E6 | 2.1 E6 | 1.4 E6 | Road capacity (J m−3K−1) | ZR | 10 | 60 | 20 | Roof height (m) | Wroof | 10 | 40 | 20 | Roof width (m) | Wroad | 10 | 40 | 20 | Road width (m) |
|
|